ARINC-629 Test and Simulation Products

Corelis ARINC-629 PCI-based and VXI-based modules provide broad ARINC-629 bus testing capabilities, multiple terminal simulation, monitoring of ARINC-629 bus traffic, and fault insertion and detection.

Product Selection Matrix

A listing of available ARINC-629 test and simulation products is provided in the following table:

Model

Description

 
PCI-629 ARINC-629 Tester Card Intelligent Single-slot PCI compatible module
PCI-629 ARINC-629 Tester Card

PCI-629 ARINC-629 Tester CardPCI-629 ARINC-629 Tester Card

The ARINC-629 PCI-629 is an intelligent single-slot PCI compatible module designed to provide broad ARINC-629 avionics data bus testing capabilities, multiple terminal simulation, and monitoring of ARINC-629 bus traffic and fault insertion and detection. One ARINC-629 channel is provided on-board that can be switched under software control to one of four 629 interfaces at the front panel of the card. The module utilizes a Boeing approved DATAC device for all normal mode data transmission and reception and it supports Periodic, Aperiodic, C mode, Block mode, Alternate, and Independent mode. The card supports 120 terminal simulation and arbitrary traffic generation. The user can connect the PCI-629 card to the ARINC-629 bus and test, simulate, monitor, and insert faults onto the bus at the maximum data rate.

Download PCI-629 Datasheet

CVXI-629 ARINC-629 Tester Module

Single-slot "C" size VXI compatible module

CVXI-629 ARINC-629 Tester Module

CVXI-629 ARINC-629 Tester ModuleCVXI-629 ARINC-629 Tester Module

The CVXI-629 is a single slot "C" size VXI compatible module designed to provide broad ARINC-629 bus testing capabilities, multiple terminal simulation, and monitoring of ARINC-629 bus traffic and fault insertion and detection. Up to four (4) fully independent ARINC-629 channels are provided on a single slot Multiple Device CVXI-629 module that contains four independent VXIbus Message Based devices, one device per ARINC-629 channel. The module utilizes the Boeing approved DATAC device for all normal mode data transmission and reception supporting Periodic, Aperiodic, C mode, Block mode, Alternate, and Independent mode. The card supports 120 terminal simulation and arbitrary traffic generation, on a per channel basis. The user can connect the four CVXI-629 channels to different ARINC 629 busses and test, simulate, monitor and insert faults on all busses simultaneously and at the maximum data rates, continuously.

Download CVXI-629 Datasheet


PCI-629 ARINC-629 Tester Card

 

PCI-629 ARINC-629 Tester Card

The ARINC-629 PCI-629 is an intelligent single-slot PCI compatible module designed to provide broad ARINC-629 avionics data bus testing capabilities, multiple terminal simulation, and monitoring of ARINC-629 bus traffic and fault insertion and detection. One ARINC-629 channel is provided on-board that can be switched under software control to one of four 629 interfaces at the front panel of the card. The module utilizes a Boeing approved DATAC device for all normal mode data transmission and reception and it supports Periodic, Aperiodic, C mode, Block mode, Alternate, and Independent mode. The card supports 120 terminal simulation and arbitrary traffic generation. The user can connect the PCI-629 card to the ARINC-629 bus and test, simulate, monitor, and insert faults onto the bus at the maximum data rate.

  • Four (4) Multiplexed ARINC-629 Channels
     

  • Intelligent Card with on-board RISC Processor
     

  • Each selected Channel (software controlled) can send and receive data simultaneously at maximum speed
     

  • Multiple Terminals Simulation capabilities, can simulate up to 120 Terminals
     

  • Extensive ARINC-629 Bus Error Injection and Detection capability
     

  • Programmable Traffic Generator mode can transmit arbitrary ARINC-629 data
     

  • On-board 4M Byte Shared Memory, expandable to 32M Bytes
     

  • High-performance interface between a host computer and ARINC-629 bus
     

  • 32-bit PCI interface, fully compliant to Revision 2.1 of the PCI Bus specification
     

  • Compatible architecture to the Corelis VXIbus based CVXI-629 card
     

  • Host Software support with Extensive "C" Library Calls and Utilities
     

  • High Reliability Boundary-Scan (JTAG) Compatible "Designed-for-Test" Module

Download PCI-629 Tester Card Datasheet


CVXI-629 ARINC-629 Tester Module

 

CVXI-629 ARINC-629 Tester ModuleThe CVXI-629 is a single slot "C" size VXI compatible module designed to provide broad ARINC-629 bus testing capabilities, multiple terminal simulation, and monitoring of ARINC-629 bus traffic and fault insertion and detection. Up to four (4) fully independent ARINC-629 channels are provided on a single slot Multiple Device CVXI-629 module that contains four independent VXIbus Message Based devices, one device per ARINC-629 channel. The module utilizes the Boeing approved DATAC device for all normal mode data transmission and reception supporting Periodic, Aperiodic, C mode, Block mode, Alternate, and Independent mode. The card supports 120 terminal simulation and arbitrary traffic generation, on a per channel basis. The user can connect the four CVXI-629 channels to different ARINC 629 busses and test, simulate, monitor and insert faults on all busses simultaneously and at the maximum data rates, continuously.

  • Four (4) Fully Independent ARINC 629 Channels
     

  • All Channels Send and Receive Data Simultaneously at Full Speed
     

  • Each of the four Channels can Simulate up to 120 Terminals
     

  • Extensive 629 Bus Error Injection and Detection Capability on all four Channels
     

  • Programmable Traffic Generator Mode can Transmit Arbitrary ARINC-629 Data on any or all channels Simultaneously
     

  • Each Channel is an Independent VXIbus Device with its own 32-bit 29030 RISC CPU
     

  • Message Based VXIbus Devices with Shared Memory Support Fast Host Data Transfers
     

  • 4M Byte Shared Memory per Channel (16M Byte Total), Expandable to 16M Byte per Channel (64M Byte Total)
     

  • Host Software Support with Extensive "C" Library Calls and Utilities
     

  • High Reliability Boundary-Scan (JTAG) Compatible "Designed-for-Test" Module

Download CVXI-629 Tester Module Datasheet

     


Did you know?

 
   
 

 

Need Assistance?

 
  If you would like assistance with implementing JTAG testing in your design, or you are simply short of resources, our talented and experienced engineering staff can help you with all your JTAG needs. Request Help

Need Assistance

* Name:
* Company:
* City:
* State/Country:
* Phone:
* Email:
Contact me by:

Inquiring About:

Additional Comments:
Need other contact information?  Click Here
 
 

 

to top

 
   
JTAG Products

JTAG Products

JTAG Interconnect, ISP, and Functional Test Solutions

Bus Analyzers

Bus Analyzers

I2C and ARINC-629 Bus Analysis Solutions

Engineering

Engineering

Request DFT Reviews, Test Procedures, and Turn-Key Solutions

Education

JTAG Education

Whitepapers, Demos, Tutorials, and Design Tips

 

Copyright Corelis 2010.  All rights reserved.

Privacy

Sitemap EWA Technologies Blackhawk DSP EWA Corporate Contact Corelis Europe